| Measuring fluid |
Liquids (20μS/cm or more) |
| Excitation |
Square wave |
| Fluid temperature |
-5 to 90 °C(Liner material: Polypropylene)
-5 to 80 °C(Liner material: Hard rubber) |
| Fluid pressure |
Subject to pressure and temperature rating of the flanges.
Note: The allowable pressure and temperature differ with the liner material. |
| Flow range |
Max.: 0 to 33928 m3/h
Min.: 0 to 0.531 m3/h |
| Flow velocity |
Max.: 0 to 12m/s
Min.: 0 to 0.3m/s |
| Size |
25 to 150mm (Liner material: Polypropylene)
200 to 1000mm (Liner material: Hard rubber) |
| Process connection |
Wafer type
JIS10K/20K, ANSI class 150/300, DIN PN16/40 |
| Materials of wet parts |
| Liner: |
25 to 150mm: Polypropylene [Standard], Hard rubber [Option]
200 to 1000mm: Hard rubber |
| Electrode: |
Hastelloy®C22 [Standard], Stainless steel/SS316 [Option] |
| Earth ring: |
Stainless steel/SS316 [Option] |
|
| Materials of body |
| Measuring tube: |
Stainless steel SS304 |
| Primary head housing: |
Carbon steel [Standard]
Stainless steel/SS304[Option] |
| Flanges: |
Carbon steel [Standard]
Stainless steel/SS316L [Option] |
| Converter housing: |
Aluminum alloy |
|
| Painting / Color |
Polyurethane resin paint / Silver |
| Accuracy |
| Indication and Pulse output: |
±0.5% of reading: For velocity 0.5m/s
±0.3% of reading: For velocity < 0.5m/s
+ velocity error ± 0.001m/s |
| Current output: |
Additional error of ±0.01mA be added to the accuracy of indication or pulse output. |
|
| Indicator |
Dot matrix LCD With backlight
Changeover (2 screens), One to three lines are displayed at one screen.
Contents of indication; Flow rate, velocity, total flow, conductivity, and coil temperature |
| Output |
Current output: 4 to 20mA DC
Pulse output: Open collector pulse |
| Standard Functions |
•Customer’s free measuring unit setting function
•Automatic zero adjustment function
•Automatic zero adjustment function
•Bi-directional flow measurement function
•Double range measurement function
•Excitation current frequency switching function
•Self-diagnosis function
•Memory save function for power fail
•Testing function
•Push button setting function
•HART communication |
| Power Supply |
100 to 230V AC (85 to 253V AC), Approx. 8 VA AC
24V DC (11 to 31V), Approx. 4 W DC |
| Protection class |
IP66/67(IEC 60529) |